Barotrauma reactor controller. Q. Barotrauma reactor controller

 
 QBarotrauma reactor controller Barodrama

Open the console. I had no idea that reactors had shielding to prevent radiation emission. You can still find them if you select this box. 0 (barring any unexpected delays), so now is a fitting time to say thank you once. Description. So long as the pump is >25% durability, the reactor operates kinda sorta as it normally would. Fire can also occur from exceeding this temperature for a different, often smaller timer duration (these durations can be found in the editor on the nuclear reactor entity). N/A. Here is picture. This frustrates most players who simply don't try to deal with the mechanic and instead use contraptions such as buffers or worse, Automated Reactor Circuits (ARC) which completely prevent overvolting by being too good. If the reactor shows power matching load then it shouldn't be the reactor causing it to lose power, something else is going on. 08 units of consumption per time for each rod. if you wanted, you could create different regexes for different reactor outputs. Investing on electrical maintenance upgrades and crew/talents can also help since that electrical room can easily flood. Barotrauma. I wire the battery charge % to the display above the battery. Its only taken me an hour to master this. by PhineasJNX. (by 2 Relay Component) the batteries are connected to 2 Relay Component that lead to the Main Junction box. Reactor efficiency can help in the beginning by stretching fuel rods but I find fuel is a non-issue by the second or third biome anyway. When your reactor overheats, it reduces the durability pretty quickly. not sure abt this one, need to actually test it. 198 votes, 58 comments. Everyone typically adds a reactor controller circuit, but it doesn't mean that I want it to come already installed. In Barotrauma you're a submarine crew member beneath the ice of Jupiter's moon. Increasing the benefits of manual reactor control is a good thing, but making reactor controllers favored by casual players unusable without any kind of in-game notice or warning is ultimately going to upset people as it's legitimately not their fault their submarine burned to a crisp because it's a known-good system that caused the fire. This causes the temperature to increase, as well as the pressure. I stand by my assertion that it feels like a bit of a cheat though, as components have no wear and tear element to them in this game which might be a factor in such a design, also it does exploit the way the reactor is coded. , creators of the STUPEDO™, THE BIG STUPEDO™, and THE DEEP STUPEDO™ - will save your boat! Six components! Ten wires! It's so simple, you couldn't think of it! The Danamo™ reactor control system is so resilient that if your sub explodes, it's the. That's good. . Barotrauma Workshop. 0000001 seconds. In Barotrauma you're a submarine crew member beneath the ice of Jupiter's moon. Controller can be turned on and off with the left switch, while the right switch can enable or disable smart docking system which sets reactor's output to 0 when docked to save fuel in campaign. Your issue is probably busted junction boxes, meaning that the power can't route from your reactor to your pumps because the interlinking junction boxes are completely broken. It started with the multiplayer version of the Iroh's Bang-Bang Reactor controller not working, so I went in and replaced the reactor controller with one that does, and published it for people to use. Finally, the light switch. 2 Automatic Control 4. F3. They contain a wealth of material loot, and often also have Creatures lurking inside. I see that there is a mixed perception on reactor controllers which sums up in what I have expected: they make your life easier at a cost and most likely once used forever used. In this guide we are going to look at a 5 component automatic reactor controller in Barotrauma, specifically on how to physically upgrade your submarine's re. Meltdown will occur if the temperature if the reactor reaches condition 0 with fuel rods in place or the reactor exceeding 6000 degrees for its meltdown timer duration. Batteries are not involved. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. 875. as far as fuel goes, I built the 7-component controller described here (it's a workshop item for a canned Assembly in the sub builder, but you can just build it by hand in-game perfectly well without downloading or installing anything); it runs far more efficiently than the stock reactor autocontroller (and will fry your junction boxes far less during evasive maneuvers. 01 * Reactor's max output) [1]" which is our Turbine output 3) Memory for 75. Well thought out automatic reactor controller systems will improve the automatic controls reaction time when adjusting fission rate and turbine output. This is useful if you find your reactor needs to be hotter to better power your ship. While the reactor needs constant adjustment when there are times where more and where less power is needed, the supply by the batteries is steady to the grid. Barotrauma. ago. The new update adds a large delay to signals going into the reactor so now the Regex-GreaterThan controller will set the reactor to the output you needed about half a minute ago instead of your current need. >Mining ore. Equip the wire on the other hand and drag it to connect it to the “SIGNAL_IN_1” connector. It's for any kind of input handling. NOTE that this won't stop reactor fire, but it will prevent reactor from exploding. Hoist the sails! This update marks the last big content update before Barotrauma 1. Supplement your player count with bots as needed in either singleplayer or multiplayer game modes. So, autoreactor nerf. Easy auto shutdown system setup. You can check the reactor durability by either going to the Status Monitor and clicking the Electrical View (green is good, red is bad), or equipping a screwdriver and pressing the Repair button. . So for gaming core number doesn't really matter. But I decided I wanted to go further so it could be used throughout the game without being. Összes Témák Képernyőmentések Alkotások Közvetítések Videók Műhely Hírek Útmutatók Értékelések. Wrecks consist of, a part of, or an entire submarine, including its cabinets and crewmembers. Sabotage playlist: reactor was only able to handle the massive spikes because I had a reactor controller setup. Press E with cursor on it (and a !screwdriver,!wire in hand), a menu will open 4. Community content is available under CC BY-NC-SA unless otherwise noted. 5). But if you keep that in mind and make sure you have 2 uranium or better rods in the reactor when needed (or all the time, the drawbacks are pretty minor), it works. IMO it may make it easier to understand for the newer folks, and also reduces a component. All Discussions Screenshots Artwork Broadcasts Videos Workshop News Guides Reviews. Dugong is a beginner-friendly, highly accessible sub. Together with the added incentives for manual operation, this should make automatic reactor control still perfectly viable but no longer the objectively best way to run a reactor. - When implementing a reactor control, you have to turn off the in game auto controller. 6 player classes with different skills and tasks: Captain, Engineer, Mechanic, Medic, Security officer and Assistant. g. In my experience the main benefit from having a reactor controller as a solo player is probably not having to replace rods as often, so with a controller one could just fill it with four rods, the controller manages the temperature, but as this is now much slower. Kastrull: 10000. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. In your picture it looks like that sub's reactor has a huge max power output. You can check the reactor durability by either going to the Status Monitor and clicking the Electrical View (green is good, red is bad), or equipping a screwdriver and pressing the Repair button. They will start exuding poisons once the infested pump is taking damage. Data is potentially outdated: Last updated for version 0. In Barotrauma you're a submarine crew member beneath the ice of Jupiter's moon. Windows in Barotrauma are actually two-piece items, consisting of the background and the window frame. But, when that pump drops below 25%, the coolant slows and stops flowing. No4Delirious [author] Oct 20, 2021 @ 11:57pm. If your concern is just using the bare minimum of electricity to operate while idling, I suggest rewiring your backup battery so it only provide electricity to mission critical devices (oxygens and controls for me). DomesMcgee. Written by No4Delirious. Steps To Reproduce. There is an automatic reactor controller wired up (Ideally your engineer learns this and other basic wiring)1- Subtract reactor load from reactor power, this will give you the ''excess power'' in your subs circuit via subtract component. The Herja has a decent power draw from its twin engines and if you're working with a default automatic reactor and not taking care with your piloting, it's real easy to set the ship afire by overvolting your boxes. u can only use the five component one. In fact, despite its relatively cheap purchase price, many players consider Dugong to be one of Barotrauma's best vanilla submarines. When your reactor overheats, it reduces the durability pretty quickly. This is all about Barotrauma – Guide for Ship Reactor for Better Automatic Control in Barotrauma; I hope you enjoy reading the Guide!The only thing left is to decide the temperature at which the Reactor will operate at. Members Online. Reactor Controller Components. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. Although I suppose as long as you aren't the one doing the. It takes 25 seconds to go from turbine 50% to 100%. Humpback: 2800. Play with friends, strangers, or your worst enemies. Award. Start with wiring (connecting) the ‘power out’ node from the Reactor to the ‘power’ node in a Junction Box. When held, it shows the interface of the controlled Nuclear Reactor, including the conditions of its Fuel Rods. Typhon 2: 5000. The load displayed in the reactor is a interpolation of the actual load (displayed in the junctionboxes) this creates a situation in which the load value is always behind the actual load. r/Barotrauma • Me managning reactor while the capitan has been bored for 0. The battery then powers the junction boxes directly. Its only taken me an hour to master this and its pretty effective at given situations. xml But if you join a server and not even those playing have any idea of the base value (because. 1K. And if there are any - not for long. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. SUBSCRIBE: me on discord: up to date on Twitter: I show you how. 4)/2 = . . I suggest using this graphite schem. Not my setup, but a simple reactor controller: Need: Greater than component, regex component, 5 wiresSlightly more advanced (but more universally helpful) is adding reactor controller. My point is not that reactor controllers on the whole are bad, they're a great upgrade project for an engineer to do, but this two component one just negates any skill, challenge, or fun with the reactor, it removes. no mods required!Description In this mod you will find: A submarine file containing pre-wired assemblies for new-style Magic Reactor Controllers for your learning pleasure. There are also fun things to do, like converting airlocks into secondary ballast tanks, or building motion sensors into the turrets that blast anything that comes close. The Herja has a decent power draw from its twin engines and if you're working with a default automatic reactor and not taking care with your piloting, it's real easy to set the ship afire by overvolting your boxes. This is a vanilla item assembly that works as improved automatic control for reactors. The single player is borderline unplayable due to how bad the AI currently is. If I could get the power and load on. the lower your helm skill is, you are just not used to use the buttons and switches on the console, thus hampering. 0% Aim Assist means the cursor has to be directly on the item's hitbox. In Barotrauma you're a submarine crew member beneath the ice of Jupiter's moon. Did u try turning off and on? the_mr_pickles • 3 yr. If a empty fuel rod is in the reactor at the same time as a full fuel rod, docking to a station will catch the reactor on fire. The unstable beta reactor is terrible, imo. This is a vanilla item assembly that works as improved automatic control for reactors. 0. Things covered:0:00 Overview0:39 Buttons, switches, levers. [1] Gesch. 2- Then add this value to the previous value you found (from multiply component) via adder component. Barotrauma. . All things a captain should have, honestly. The ROAD system is compatible to official submarines. I feel like nerf of auto-reactors in Barotrauma is just like Whiplash nerf in ULTRAKILL : was needed, but too hard. >Finds Fulgurium Fuel Rod. Members Online • Electronic-Lynx-9771 . -Wire a connection from the Text Display's setText (iirc) to the reactor's fuelLeft (iirc) -Have the captain yell at you when it goes below 10, 20 for 2 rod config. 117K views 3 years ago. 2. Flee or fight alien lifeforms, explore a strange new world, command your crew, and craft equipment in a tense 2d co-op experience. I can upload screenshot if needed, but my wiring and components are the same as all the video, so im curious why nothing is happening. About RCC and Battery Buffer. #footer_privacy_policy | #footer. In Barotrauma you're a submarine crew member beneath the ice of Jupiter's moon. For gaming most games can't (or very inefficiently) use multiple cores. My point is not that reactor controllers on the whole are bad, they're a great upgrade project for an engineer to do, but this two component one just negates any skill, challenge, or fun with the reactor, it removes. 5-component is frequent version that will prevent many issues with reactor and allow have much less over/undervoltages in general. IMO it may make it easier to understand for the newer folks, and also reduces a component. You can see the current status of your reactor by looking at its sprite. Attach certain electrical Wiring Components to the wall next to the reactor and wire their signal_in and signal_out to the reactor. All Discussions. Made clown and husk events and missions more common. Both Submarines failed to output any power the moment she ship left dock. 04 units of consumption per time for each rod. #4. 742 votes, 37 comments. You can liken it to the cruise control system on a car, controlling the accelerator to maintain a certain speed. I suspect it makes for some odd things happening with some items. 3. This is a minor annoyance when using reactor control circuits. Remora. Welcome to Europa!. Info Tab. Yeah the control system is legit, but as you said, not for nuclear reactors. Since the submarines are pretty big so, you will get to allocate your crew or even real players in Co-op and Multiplayer modes. Generally I don't have a bot manning the reactor, I either have it on auto or there's a reactor controller fitted, I just check it occasionally for fuel level (an indicator can easily be wired up to the bridge nowadays). With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. we used it once and went back to typhon 2. perhaps a little too powerful. ago. Regex is an electrical component used in the submarine game, Barotrauma, to find key phrases within the information of other components. This was installed on the Kestral, the second value showed at 4999 (I give the mouse a good wiggle) is the ships maximum power potential, determined by winding the turbine fully while manually balancing heat. I usually just send a wire from the Reactor_Power_Out to a NOT component signal in and wire the emergency lights to the NOT component signal out. LtDWolf • 1 yr. The reason it's getting nerfed, from what I've heard, is that it goes against the Dev's vision of having the electrical engineer stay at the reactor to manually adjust the reactor. 3 of them are new reactors made by me, and 1 of them is the famous two component reactor. The dev team has effectively neutered ALL (AND I MEAN ALL) custom auto reactors down to the shitty vanilla auto reactor. Most of the doors and. Function. Knowlton V2. They are the target of Salvage Missions. If reactor is badly damaged wear a diving suit (PUCS grants high resistance) and stack with a hazmat suit and iodide potassium before proceeding as usual to prevent getting instantly fully irradiated/contaminated. That's what makes reactor controllers so simple: the reactors as they are now are actually pretty flexible. Barotrauma. SUBSCRIBE: me on discord: up to date on Twitter: I show you how. 1. The automatic reactor controller can be run with multiple fuel rods, it's just that it can't handle the jump from one. Although I suppose as long as you aren't the one doing the. It works great, however You should also add an automatic meltdown reactor shutdown just in case. Barotrauma. I made an automatic reactor circuit. This is just one solution, for a very common case. . Without any knowledge: does the reactor have fuel/is on. My problem is: if the 2-comp reactor is viable enough. I can just offer you the guide here, it has several different reactor controllers to choose from. r/Barotrauma • Me managning reactor while the capitan has been bored for 0. This one takes into account the slider rate limits so it never moves fission rate too fast for turbine to keep up, and the preslide. The Kastrull's reactor consumes fuel 50% faster than normal, and its maximum output is only 5,000kw. Here are some things to consider. 3 Fuel 2. When the components are correctly configured the sliders will bounce between 0 and 100. The main issue would be to be sure the message is only broadcasted once (or at least once ever 10 sec) so you might want to add a check that only reset once you have changed the fuel rod (value get higher than 10). 6GHz. Edit: I found it on the Magic Reactor Controller workshop item, so I see it is using real world principles. Thorium and Fulgurium rods may generate more heat when inserted, but with the typical 5 component reactor controller attached you can shove four fulgurium rods in from cold and it won't catch fire. You connect smoke detector output to a relay with 'signal 1' and 'set state' meaning if detector sends 0 (meaning no smoke) it shuts down whole relay and any signal is blocked until detector sends a 1. To overvolt or undervolt, simply multiply the load by the desired voltage before sending it into the circuit. Now, press ESC to exit. And that means less fried boxes. Barotrauma. I wish to create a load balancing system on the post side of the batteries and not on the pre side where the reactor resides. With a reactor controller circuit installed you can load two or three rods (four if you're me, because why not) which will give longer run time between refuelling. The turbine control controls how fast the turbines inside the reactor spin, and can limit the amount of power produced. By subtracting the load created by the capacitors from the load value used by the reactor controller that additional load is now invisible to the reactor. When the nuclear reactor is producing too much, the batteries should take in excess power to store. So me and my friend have just recently started the game, however I (the sub engineer) run in multiple issues with the reactors both in the Dugong and Camel, where automatic control wouldnt work and the reactor would always scram, and so I had to manually control it, and there were some huge dips and spike in load constantly, going from 4500 KW all the way into the 2000 KW in a span of a second. This issue was present before the implementation of the current solution, which did not address the underlying. This variant of the 2-component reactor controller automatically stops power production when docked!Keep in mind, if the thing you're docking with doesn't su. It reacts very fasts to load fluctuations which helps to prevent overvoltage and. (and I think it wastes fuel as well but I'm not 100% on how the reactor works) if power is less than load things simply. The load displayed in the reactor is a interpolation of the actual load (displayed in the junctionboxes) this creates a situation in which the load value is always behind the actual load. In control theory, a bang–bang controller ( hysteresis, 2 step or on–off controller), is a feedback controller that switches abruptly between two states. Not my setup, but a simple reactor controller: Need: Greater than component, regex component, 5 wiresSo long as the pump is >25% durability, the reactor operates kinda sorta as it normally would. false output should be zero. All Discussions Screenshots Artwork Broadcasts Videos Workshop News Guides Reviews. Flee or fight alien lifeforms, explore a strange new world, command your crew, and craft equipment in a tense 2d co-op experience. Although I suppose as long as you aren't the one doing the. Flee or fight alien lifeforms, explore a strange new world, command your crew, and craft equipment in a tense 2d co-op experience. If not, double click the power button. The problem with Azimuth is it only have one super capacitor. 0. It was a catastrophe we amazing pulled back from. I'm happily sailing towards the end of the second biome, no reactor controller and for most of the time, one fuel rod at a time. Just search for reactor controllers in workshop and U'll find his variants. You can use them to create virtual rooms behind doorways, with functional furniture, to reduce clutter and. it uses an PI controller to manage the reactor load. It is not sold. Rhapsody Apr 10 @ 7:39am. Safe operating temperature of reactor is between 4000 and 6000, by default internal automatic mode will set temperature at 5000. I've added a section with answers for your other questions. you either need to buffer the engine with dedicated batteries or you need to use manual control on the helm to slowly ramp up engine thrust instead of jacking it to 100% immediately. Component Based Reactor Controller. Favorite. Banäne Nov 20, 2021 @ 5:01am. The controller can hand four rods of any kind without overheating or providing over voltage. Yes, you should adjust the value when upgrading reactor's max power, however in most cases the difference is small enough that not updating the value won't outright break the controller, just make it provide a bit less power. 9. A Workshop Item for Barotrauma. Barodrama. Move blank circle with wire onto "Detonate" circle then exit by pressing right mouse outside the menu 5. If this gives you strong feelings (awe, shock, disgust, confusion, happiness, love, loss of sense of taste or smell), consider joining the Barotrauma Discord and saying hello in #baro-sub-building. When the nuclear reactor isn't producing enough, the battery will output as much as it needs to in order to make up for the gap in power load. You can do this with a quick and dirty reactor controller. I think it's fun to be able to use 1 component and 3 wires to control the entire reactor. Members Online. This causes the temperature to increase, as well as the pressure. - Put info panel on bridge about your battery state and add a toggle switch to turn them on and off. It's a logic system made to adjust the values on the reactor so as to make it better react as the electrical load increases and decreases. By DrFreenote. I like to mess around with electrical stuff so I picked engineer role, did this during peacfull moments of our adventures Automatically calculates reactor fuel % left with any rod count and type inserted in reactor. I've added a section with answers for your other questions. both due to layout and turret placement/coverage. In Barotrauma you're a submarine crew member beneath the ice of Jupiter's moon. How to instantly to blow up reactor without melting - barotrauma sabotage / traitor tutorial. The 2 component. 74 votes, 29 comments. Description. 2kW of other stuff to charge like guns and fab), sudden changes from fast to slow (vice versa) easily overwhelm the reactor and junction boxes if there isn’t an engineer manning the reactor, even with the reactor controller. In-depth Reactor Guide and Fission Controller (last updated for 0. Best way to deal with power spikes without sub editor is:Making automated reactor controll from components. Barotrauma is a game of complete chaos in a stressful and volatile environment. Összes Témák Képernyőmentések Alkotások Közvetítések Videók Műhely Hírek Útmutatók Értékelések. The thing to remember about reactor controllers is that most of the commonly known designs do not take into account environmental high load influences, if one of these factors sends the load sky-high then the fission rate could be. Barotrauma. If the reactor shows power matching load then it shouldn't be the reactor causing it to lose power, something else is going on. I can just offer you the guide here, it has several different reactor controllers to choose from. Reactor Off After Docking system (ROAD) is aiming to achieve: The reactor will automatically stop consuming fuel rods when connected to a powered outpost, but remain working when docked to abandoned outpost or docked by shuttles. Written by No4Delirious. Some ship builders make a logic circuit using a memory. It used a logic control system to make sure the output of the reactor always matches the demand of the battery it is connected to. That's more than twice the improvement, and thus still a good reason to keep on tinkering with the reactor controller components, while at the same time bringing back power management that the devs intended. To be honest, with those Uber powerful reactor control circuits, the only reason to BE an engineer was for the tree. Barotrauma. Humpack, Poor drainage, only one big pump, ON THE REAR!Barotrauma submarine editor tutorial. Collection of short tips for every class and some class variants too! <!---NUCLEAR ENGINEER TIPS---> 1-Most devices only require half the energy (required voltage is 0. by DarthJig011. RegEx is OP. So is there a mod that changes it or something we can do?The reactor's automatic control can be made more efficient. The fission rate controls how the fuel rods are reacting, making the reactor hotter or colder as needed. More advanced: Add cameras / search lights to several places around your ship, use a single periscope. Although I suppose as long as you aren't the one doing the. " -wiki Last edited by McGarnagle; Dec 12, 2021 @ 2:21am #5. 4)/1 = . I say almost, since it due to the way reactors interpolate the actual system load, achieving instant response to the actual system load is near impossible. Credit for the 7-component controller: value (output=1; false output BLANK; use captur. Add a Comment. 53K subscribers in the Barotrauma community. What this means is that the System won't be active at all times but only when bad things happen (e. From beginners to experts, you'll find everything you need to build the ultimate reactor controller in Barotrauma. The reactor is giving constant power to the battiers, and the batteries are regulating the poweroutput automatically. I've been playing th. Fixed anaparalyzant not reducing paralysis. 77 Sort by: Open comment sort options Andargor • 8 mo. The Reactor PDA is a portable tool. Now there is a reason to attend the reactor and even a bonus for doing so. 2*. By Drifter. People do not want their ship to be overpowered, whether in terms of weapons or management challenges. 0 (barring any unexpected delays), so now is a fitting time to say thank you once. You said it happens every 5 minutes, it’s most likely due to an action by one of the crew. An. Automating turbine output control was easy, since it's just a straight percentage of max power out of the reactor. This was installed on the Kestral, the second value showed at 4999 (I give the mouse a good wiggle) is the ships maximum power potential, determined by winding the turbine fully while manually balancing heat. The sub has a built-in reactor controller. Nuclear power reactors produce energy by initiating and controlling a sustained nuclear chain reaction. wiring up a reactor controller and automatic lighting in the. That's 80*2=160 FUEL_OUT. 1. #3. Right. An engineer could fit a reactor controller circuit but in general I think this should be for quality of life rather than an essential thing, i. Here is what I did: Step 1 is automate the reactor. Sabotage playlist: reactor was only able to handle the massive spikes because I had a reactor controller setup. Once that gets above a certain threshold, alarms start to go off, as well as the RCS Fault alarm. See full list on gist. When I tried to fix this using a reactor controller, I found that it completely negated ANY interaction with the reactor at all. 12/11/2022 DrFreenote No Comments. The new reactor sucks. Description. It acts as the submarine's main power source for all installations. You can alter the expression of the REGEX component [1-x] to be as high as 9. His name instantly disappeared as well as 60% of our subs hull, humpback lost its reactor, half of medbay, half of fabricator, and half of battery room and the entire rear ballast. "It allows full remote control of a submarine's nuclear reactor, except for the movement of fuel rods. Written by No4Delirious. (There are some great schematics on barotrauma steam workshop page)In Barotrauma you're a submarine crew member beneath the ice of Jupiter's moon. The Greater Than Component compares the power and load of the reactor to control the turbine. I'm wondering if anyone has fully upgraded the orca 2 and if it can get to the point where reactor output can meet the load with uraniumExample: reactor has 2000 max output, submarine somehow reaches 4000 load, which causes the controller to calculate turbine value of 200 and set the fission rate based on that 200, but since the turbine can't be set higher than 100 now the fission rate is 2x higher than it should be which can result in a reactor meltdown. I think as soon as an engineer sees how effective pretty much any reactor controller is at saving the junction boxes from over-volting and thus extra repair time, and also allows four rods inserting at once thus saving the engineer the duty of babysitting the reactor because a single fuel rod runs out very quickly, they will always want to. Nuclear reactor and power grid. $6. I was mastering my reactor job as engineer for a few missions, came up with keeping temperature at the minimal possible level to produce energy to save rod/rods charge, so I was keeping temperature level equal to the lowest orange temperature bar and, of course, was adjusting turbine output to stay in green zone. Silent running is mostly just turning off your sonar. ) Then you have the REALLY good. Although I suppose as long as you aren't the one doing the. Just search for reactor controllers in workshop and U'll find his variants. Congratulations, it is very well made. Most vanilla subs are around 2,700 - 10k. This guide does not build a turbine controller. 2 is enough for full power, but a set of 4 rods with varied amounts of durability will allow you to replace them 1 at a expired. This is a list of the default controls. Wow, this is a truly breathtaking piece of writing, design, and criticism. Important: Add behavior logic to the. If the turbine limit is too low, the reactor cannot use it's. The Bang Bang reactor controller not working for you in the Hoist the Sails update? Here's Jash's best fix for the latest version. Few days ago I got saw a post about Battery Buffer circuit that was made in anticipation of the nerfs to Reactor Controller Circuit, even though the nerfs were small enough that minor adjustments to it could fix, I still had an idea in my head, what's about combining those two? Imagine a RCC that works in tandem. So if you add a second rod it would be: (. I'm wondering if anyone has fully upgraded the orca 2 and if it can get to the point where reactor output can meet the load with uraniumNot so, this is a reactor controller that works quite well Formulas are Turbine output = Load value / (0. This guide does not build a turbineWeld doors shut and flood areas to trap and drown people.